Condition Monitoring for Mechanical Faults in Fully Integrated Servo Drive Systems
| [View]
[Download]
|
Author(s) |
Jesus Arellano-Padilla |
Abstract |
A modified motor current signature analysis (MCSA) approach to monitor the performance of a servo drive system using only one set of current transducers at the input side of the rectifier is proposed. The paper introduces a mathematical analysis to determine how the harmonic frequencies related to a fault propagate from the motor to the input inverter, and includes the effect of the DC Link components. Experimental results are presented for a Permanent Magnet servo drive system with faulty bearings to validate the proposed scheme. |
Download |
Filename: | 556.pdf |
Filesize: | 476.3 KB |
|
Type |
Members Only |
Date |