Please enter the words you want to search for:

[Return to folder listing]

   Condition Monitoring for Mechanical Faults in Fully Integrated Servo Drive Systems   [View] 
 [Download] 
 Author(s)   Jesus Arellano-Padilla 
 Abstract   A modified motor current signature analysis (MCSA) approach to monitor the performance of a servo drive system using only one set of current transducers at the input side of the rectifier is proposed. The paper introduces a mathematical analysis to determine how the harmonic frequencies related to a fault propagate from the motor to the input inverter, and includes the effect of the DC Link components. Experimental results are presented for a Permanent Magnet servo drive system with faulty bearings to validate the proposed scheme.  
 Download 
Filename:556.pdf
Filesize:476.3 KB
 Type   Members Only 
 Date   Last modified 2008-12-07 by System