Please enter the words you want to search for:

[Return to folder listing]

   50kVA Regenerative Active load for power test system    [View] 
 [Download] 
 Author(s)   BAEK Ju Won 
 Abstract   This paper presents 50kVA active load with low loss, which regenerate the power to utility. To make the regenerative load, 3 phase back to back inverter using DSP320C33 have been made and tested. One inverter control the power flow of the test system and the other control the regeneration of the power to utility. It could be used as a nonlinear load, resistive load, and reactive load for single phase AC, DC, three phase AC. Also, load step change and unbalanced load is simply implemented by the proposed converter. The 50kW prototype is made and tested to verify the regenerative load function.  
 Download 
Filename:0506-epe2007-full-04354204.pdf
Filesize:670.2 KB
 Type   Members Only 
 Date   Last modified 2008-01-11 by System