   Influences of magnetic inductance, leakage inductance and saturable inductance on an active clamp forward converter   [View] 
 [Download] 
 Author(s)   REIMANN Tobias ; DEBOY Gerald; PETZOLDT Juergen; TIAN Jian; SCHERF Marko 
 Abstract   In this paper, the influences of the magnetic inductance, leakage inductance and saturable inductor on the behaviour of the active clamp forward are analyzed, and their mathematic solutions are given. Based on the analysis, the other topology variant is proposed, which can be used to reduce the oscillation across the freewheeling switch and improve the ZVS condition of the auxiliary switch in primary side. This leads to improve the EMI behaviour and efficiency because the low voltage rectifier switches could be used. To verify these analyse, some experimental results are presented. 
 Download 
Filename:0104-epe2007-full-12132415.pdf
Filesize:314.6 KB
 Type   Members Only 
 Date   Last modified 2008-01-11 by System