Please enter the words you want to search for:

[Return to folder listing]

   Reduction of common mode currents generated by three-level inverters with consideration of motor overvoltages   [View] 
 [Download] 
 Author(s)   BAUDESSON Philippe; LE MOIGNE Philippe; IDIR Nadir; FRANCHAUD Jean-Jacques; VIDET Arnaud 
 Abstract   In adjustable speed drive applications, the switching of the inverter semiconductors generates common mode currents as well as harmful overvoltages on the motor terminals when long cables are used. Consequently, bulky and expensive input and output filters must be used. This work aims at reducing these disturbances from their origin by using a three-level neutral-point-clamped (NPC) inverter controlled with a new pulse-width-modulation (PWM) strategy. Whereas previous common mode noise-reducing strategies usually generate higher overvoltages than conventional ones, the proposed PWM is able to manage both problems thanks to its internal degrees of freedom. 
 Download 
Filename:0062-epe2007-full-21313396.pdf
Filesize:1.406 MB
 Type   Members Only 
 Date   Last modified 2008-01-11 by System