   Advantages of using Two-Switch Forward in Single-Stage Power Factor Corrected Power Supplies   [View] 
 [Download] 
 Author(s)   L. Petersen 
 Abstract   A single-Stage power factor corrected power supply using a two-switch forward is proposed to increase efficiency. The converter is operated in the DCM (Discontinues Conduction Mode) and it will be shown that this operation mode insures the intermediate DC-bus to be controlled only by means of circuit parameters and therefore independent of load variations. The DCM operation often has a diminishing effect on the efficiency but it will be shown that high efficiency with minimum circuit complexity can be achieved in this mode. A 500W 70V prototype of the two-switch Boost-Forward PFC power supply has been implemented. The measured efficiency is between 85% and 88.5% in the range 30W-500W and the measured power factor at full load is 0.95. 
 Download 
Filename:Unnamed file
Filesize:129.7 KB
 Type   Members Only 
 Date   Last modified 2006-02-20 by System