High frequency stator ground currents of inverter-fed squirrel-cage induction motors up to 500 kW
| [View]
[Download]
|
Author(s) |
A. Muetze; A. Binder |
Abstract |
One type of bearing currents that occur at inverter-operation is the high frequency circulating bearing
current. This current is induced by the high frequency stator ground current of the motor. Such stator
ground currents have been investigated within a research program for systematic investigation of the
influence of different system parameters on inverter-induced bearing currents on power levels 11 kW
to 500 kW. This paper discusses the influence of motor size, motor-inverter-combination, motor cable
type and length and passive filters on the high frequency stator ground currents. |
Download |
Filename: | EPE2003-PP0027 - A. Muetze |
Filesize: | 387.3 KB |
|
Type |
Members Only |
Date |
Last modified 2003-10-13 by Unknown |
|
|