   Comparison of Excitation Signals for Low and Zero Speed Estimation of the Rotor Position in an Axial Flux PMSM   [View] 
 [Download] 
 Author(s)   S. Ovrebo 
 Abstract   Sensorless control of PMSM at low and zero speed requires injection of a test signal to extract information on rotor position. Two methods are commonly used for this excitation: the INFORM method and injection of a high frequency carrier signal. This paper describes the comparison of the two types excitation signals applied to a prototype axial flux PMSM. The paper gives an evaluation of what excitation that would be preferred for the specified prototype machine. 
 Download 
Filename:Unnamed file
Filesize:192.5 KB
 Type   Members Only 