Please enter the words you want to search for:

[Return to folder listing]

   Sensorless Control of Salient Pole PMSM Using a Low-Frequency Signal Injection   [View] 
 [Download] 
 Author(s)   ESKOLA Matti; TUUSA Heikki 
 Abstract   This paper deals with sensorless control of permanent magnet synchronous motor. The low-frequency signal injection estimator is studied in the case of salient PMSM. If there is an error in the estimated position, the injected signal creates a torque oscillation and affects the back-emf. The oscillating back-emf can be used to track the position and speed. The saliency of the PMSM is a disturbance for the low frequency estimator. In this paper the effect of saliency is analysed in steady state and a simple method to compensate the saliency effect is proposed. The performance of the method is verified by measurements. 
 Download 
Filename:0932
Filesize:589.9 KB
 Type   Members Only 
 Date   Last modified 2006-02-08 by System