   Impacts of Cross-Saturation on Sensorless Control of Surface Permanent Magnet Synchronous Motors   [View] 
 [Download] 
 Author(s)   FRENZKE Thorsten 
 Abstract   Cross-magnetisation complicates the sensorless control of non-salient ac machines, like surface magnet synchronous motors. The motor currents influence position estimation techniques for low speed based on "saturation induced" saliencies. This paper considers cross-saturation effects to explain the magnetic-axis shift under loaded conditions and discusses the influence of the operating point on the saliency. A finite element analysis and lab measurements validate the results. 