   Control strategy for hybrid active filters leading to reduced inverter rating   [View] 
 [Download] 
 Author(s)   ASIMINOAEI L.; DANIEL BENJAMIN Doniga; GEORGE DAN Stan; TEODORESCU Remus; MAGUREANU R.; BLAABJERG Frede 
 Abstract   In this paper a parallel hybrid filter is studied for current harmonic compensation. The hybrid filter is formed by a single tuned LC filter per phase and a small-rated power three-phase active filter, which are directly connected in series without any matching transformer. The required rating of the active filter is much smaller than a conventional standalone active filter would be. No additional switching-ripple filter is required for the hybrid filter because the LC filter functions not only as a harmonic filter but also as a switching-ripple filter around 10 kHz. Simulation results and experimental results obtained in laboratory confirmed the validity and effectiveness of the control. 
 Download 
Filename:0014
Filesize:388.6 KB
 Type   Members Only 
 Date   Last modified 2006-02-05 by System