Five Level Neutral-Point Clamped Inverter for a Dynamic Voltage Restorer
| [View]
[Download]
|
Author(s) |
DE DONCKER Rik W.; ROMAUS Christoph; MEYER Christoph |
Abstract |
DVRs are of utmost importance to secure sensitive loads from voltage sags. Especially, in medium-voltage grids the demand for securing larger loads has increased significantly. Installing higher power levels leads to the consideration of multi-level converters with an increased number of levels. Therefore, the 5-level NPC could be an interesting solution. The drawback of this topology is that its voltage levels are not stable for active power transmission. This paper presents a method to allow a short-time stable operation of this topology - without oversizing the DC-link capacitor - and therefore the usage of this converter for DVR applications. |
Download |
Filename: | 0649 |
Filesize: | 480.7 KB |
|
Type |
Members Only |
Date |
Last modified 2006-02-05 by System |
|
|