Inverter DC-Link Stabilizing Control with Improved Voltage Sag Ride-Through Capability
| [View]
[Download]
|
Author(s) |
PIETILAeINEN Kai; HARNEFORS Lennart |
Abstract |
Previously published results concerning instability of the dc link in inverter drives fed from a dc grid or via a rectifier are extended in this paper. It is shown that rectifier-inverter drives equipped with small (film) dc-link capacitors may need active stabilization. The impact of limited bandwidth and switching frequency in the inverter-motor current control loop is considered. Recommendations for selection of the dc-link capacitor, the switching frequency, and the dc-link stabilization control law in relation to each other are given. The control law is incorporated in a previously proposed current controller, which is designed for good voltage sag ride-through capability. |
Download |
Filename: | 0586 |
Filesize: | 1.405 MB |
|
Type |
Members Only |
Date |
Last modified 2006-02-05 by System |
|
|