 Author(s)   RENKEN Folker 
 Abstract   In case of controlling a pulsed single-phase H-bridge inverter with two and three voltage levels the capacitor currents in the dc-link circuit are calculated analytically. For these calculations first a sinusoidal modulated voltage and sinusoidal current at the output of the inverter are presupposed. Afterwards the additional load of the dc-link capacitors caused by harmonic currents of the output filter circuit is examined. For this reason the individual harmonics of the dc-link current with sinusoidal and with overlaid harmonic output currents are calculated with help of spectral analysis. At last the influence of the switching processes to the dc-link circuit load is discussed. The theoretically determined currents in the dc-link capacitors are compared with several practical measurements. 
 Download 
Filename:0019
Filesize:811.5 KB
 Type   Members Only 
 Date   Last modified 2006-02-05 by System