   Safety operation locations of permanent magnet synchronous machine for stand alone wind energy converter   [View] 
 [Download] 
 Author(s)   E. J. R. Sambatra; G. Barakat; B. Dakyo; X. Roboam 
 Abstract   This paper deals with the study of the safety operation zones of permanent magnet synchronous generator directly coupled to the turbine of a stand alone wind energy converter. First, the model of each component constituting a stage in the path of the conversion is proposed and implemented in Matlab environment. Then, based on simulation results, the different operation regions of the permanent magnet synchronous generator are determined and analysed. These simulation results provide accurate informations which will be helpful for permanent magnet synchronous machine design and system control operation. 