Please enter the words you want to search for:

[Return to folder listing]

   The New Technique For Low Power Consumption Of Power Supply   [View] 
 [Download] 
 Author(s)   Jin-Ho Choi, Young-Cheol Ryu 
 Abstract   SMPS losses consist of switching loss, conduction loss, and core loss. In case of light load the switching loss takes the most things in SMPS. Conventional burst mode operation meets the requirement of low power consumption. But, it is not sufficient for Low frequency switching at no-load condition to provide the source of IC’s Bias. High frequency switching increases switching loss of SMPS. Moreover recently lower stand-by power, the input power of about 0.09mW at the no-load condition, is required. This paper presents that during the burst mode decreasing IC’s consumption power at the internal block makes system high efficient and prevents malfunction at the minimum load. 
 Download 
Filename:A65344
Filesize:180.6 KB
 Type   Members Only 
 Date   Last modified 2006-02-16 by System