Improvement Of Ability For Dc Current Interruption By Diverting Circuit
| [View]
[Download]
|
Author(s) |
Akira Sugawara(jp), Tsukasa Furuse(jp), Kouichi Itagaki(jp), Hazairin Samaulah(id), Masami Takada(jp) |
Abstract |
For interruption of DC circuit current using a
small relay, characteristics of arc duration time for the relay
contacts are measured. A diverting element is connected to
parallel with the relay contacts. As the diverting element, a PTC
(Positive Temperature Coefficient Resistor) or a capacitor is
used. It is desirable that the initial resistance of the PTC is
small and that the capacitor can sufficiently absorb the arc
current. By parallel connecting a diverting element with a pair
of relay contacts, it is possible that arc duration time between
relay contacts shortens. |
Download |
Filename: | A1445 |
Filesize: | 111.6 KB |
|
Type |
Members Only |
Date |
Last modified 2006-02-15 by System |
|
|