   Comparative Study of Starting Methods for a Single-Phase Permanent Magnet Synchronous Motor   [View] 
 [Download] 
 Author(s)   M. Popescu; T.J.E. Miller; C. Cossar; M. McGilp; G. Strappazzon; N. Trivillin; R. Santarossa 
 Abstract   
This paper compares three starting methods for a single-phase interior permanent magnet synchronous motor. One is a line-start capacitor motor with a starting cage. The second is the same cage motor with an open-loop variable-voltage fixed-frequency inverter. The third uses the same motor without its starting cage, fed from a closed-loop current-regulated inverter with shaft position feedback. The computed starting performance is compared with test data for all three cases.
 
 Download 
Filename:Unnamed file
Filesize:266.9 KB
 Type   Members Only 
 Date   Last modified 2006-04-19 by System