Please enter the words you want to search for:

[Return to folder listing]

   Parameter Independant Phase Tracking Method for Sensorless Control of PWM Rectifiers   [View] 
 [Download] 
 Author(s)   P. Szczupak; M. Linke; R. Kennel 
 Abstract   
In this paper a new parameter independent sensorless control strategy for a voltage oriented controlled (VOC) threephase pulsewidth modulated (PWM) power supply rectifier is presented. This control method requires neither the measured AC-line voltages nor any accurate circuit parameters for estimation purposes. Furthermore there is no need for additional test signals. There are no additional hardware requirements with respect to the standard drive invertersavailable in the market which usually are not equipped with AC-side voltage sensors. It will be seen that the calculation demand for the sensorless approach is negligible in comparison to the requirements for the control itself. This approach makes use of the slow varying AC-line voltage - the sample frequency of the inverter is at least ten times higher. The principle of the proposed method is explained, and its effectiveness is proven experimentally.
 