   Rotor cage losses of an inverter-fed PMSM investigated with FEM   [View] 
 [Download] 
 Author(s)   P. Thelin; H.-P. Nee; J. Soulard; C. Sadarangani; J. Timmerman 
 Abstract   In the design of a compact inverter-fed buried permanent magnet synchronous motor, the high-frequency losses of the sparse rotor cage - which are difficult to predict - were assumed to be small. To investigate these ohmic high-frequency losses of the rotor cage, fixed-speed time-stepping 2DFEM calculations have been carried out. The losses due to only the magnets, magnets and sinusoidal currents, high-frequency currents etc., and the actual currents are presented. The actual current wave-forms were obtained from measurements on the manufactured prototype motor. 
 Download 
Filename:EPE2003-PP0691 - Thelin
Filesize:620.9 KB
 Type   Members Only 
 Date   Last modified 2004-02-05 by Unknown