   Modeling a 80 kV Pulse Source for Pulsed Electric Fields (PEF)   [View] 
 [Download] 
 Author(s)   B. Roodenburg; S. W. H. De Haan; Y. L. M. Creyghton; J. Morren; H. A. Prins 
 Abstract   In laboratories food treatment with Pulsed Electric Fields (PEF) is commonly used these days. Using this treatment method, the food is pasteurized due to the high electric field and not by heating. Because of some technical problems this technology is not common used on industrial scale. Scaling the laboratory treatment installations to an industrial application is one of the main problems. The service life of the used components is an important aspect. If we want more clearness about the lifetime expectancy, a good contact with the component designer is necessary. It is also very important that we can specify the voltage and current rating of the components accurately. To obtain the highest system performance at minimal costs the development and validation of models is required. For an electric PEF installation with a VLCS (voltage limited current source), PFN (Pulse Forming Network), thyratron and pulse transformer models are developed and validated. 
 Download 
Filename:EPE-PEMC2002 - T5-006 - Roodenburg.pdf
Filesize:1.085 MB
 Type   Members Only 
 Date   Last modified 2004-05-25 by System