   Power losses evaluation of the half bridge configuration parallel – loaded resonant DC-DC converter controlled with constant frequency   [View] 
 [Download] 
 Author(s)   W. Wojtkowski 
 Abstract   In this article power losses in the half bridge configuration, parallel – loaded resonant DC-DC converter controlled with constant frequency are considered. A comparison between power losses in semiconductor elements in a DC/DC converter controlled with constant frequency and power losses in equivalent DC/DC converter controlled with variable frequency is presented. A breadboard system has been built to experimentally verify the models and to complement the theoretical work. 
 Download 
Filename:EPE-PEMC2002 - T1-028 - Wojtkowski.pdf
Filesize:354.4 KB
 Type   Members Only 
 Date   Last modified 2004-05-12 by System