Abstract |
A high power Wind Energy Conversion System (WECS) connected to isolated loads is considered
in this paper. As the WECS must work without auxiliary source, ensure the balance generation –
consumption, set the adequate frequency and voltage, it is combined to a Flywheel Energy Storage
System (FESS). For the WECS, we have considered a Variable Speed Wind Turbine (VSWT) coupled
to a Permanent Magnet Synchronous Generator (PMSG). A control strategy of this system is
proposed. As loads are not necessary balanced, it is proposed to control directly the alternating line-toline
voltage of the network with the help of resonant controllers. The performance of the proposed
global system is analyzed with the help of simulations. |