   Minimisation of commutation delays in power converters   [View] 
 [Download] 
 Author(s)   M. Bland; C. Silva; P. Wheeler; L. Empringham 
 Abstract   This paper describes a simple solution to waveform distortion problems caused by dead-time and zero current clamping in AC power converters. With the proposed method it will be possible to safely reduce the dead-time to an absolute minimum, making any errors caused by the dead-time negligible. The method described can be applied to any IGBT based switching circuit where dead-time is used. The application of the proposed method to two different types of AC converters is discussed. Practical results are presented with the implementation of the method in a Voltage Source Inverter (VSI) and in a Matrix Converter. The commutation processes in Matrix Converter and VSI circuits is discussed and the limits of safe commutation are investigated. 
 Download 
Filename:EPE2003-PP0353 - Bland
Filesize:1.228 MB
 Type   Members Only 
 Date   Last modified 2004-01-21 by Unknown