   Magnetic Field in Surroundings of Induction Motor   [View] 
 [Download] 
 Author(s)   Chmelík K., Vachala A. 
 Abstract   High reliability is one of the most important requirements of technical operations and can be assessed by estimation of the actual operational state. This operation is called technical diagnostics. Magnetic induction around an induction motor is taken as a value indicating the state of its functional properties. We practise modelling of magnetic field around the induction motor by means of the ANSYS program in order to get information about the shape of the magnetic field and about the size of magnetic induction both outside a faultless induction motor and a motor with an eccentric air gap. The results are then checked by measuring the outside magnetic field of the induction motor during its operation by means of the BELL apparatus.  
 Download 
Filename:EPE-PEMC2000 - 070 - Chmelik.pdf
Filesize:286 KB
 Type   Members Only 
 Date   Last modified 2004-04-28 by System