Please enter the words you want to search for:

[Return to folder listing]

   Minimization of Current Harmonics of DTC Controller Using a Suitable Switching Pattern   [View] 
 [Download] 
 Author(s)   Faiz J., Sharifian M.B.B.*, Fedák V.** 
 Abstract   In this paper direct torque control (DTC) technique is used for induction motor control. Because of high switching frequency, non-pulsed width modulation (NPWM) techniques are frequently preferred. Four different switching algorithms using hysteresis and non-hysteresis controllers are proposed and compared. The harmonic spectra of the stator voltage, current and torque are determined and compared in the above techniques. The results indicate that the non-hysteresis controllers have lower initial expense and current cost (consumed power, and current and torque ripples) compared with the hysteresis controllers. Among these algorithms, the non-hysteresis controllers called two-band flux controller and triple-band torque controller lead to a better result with an advantage of simpler control algorithms.  
 Download 
Filename:EPE-PEMC2000 - 021 - Faiz.pdf
Filesize:257.7 KB
 Type   Members Only 
 Date   Last modified 2004-04-28 by System