Please enter the words you want to search for:

[Return to folder listing]

   A Sliding Mode Control Design of an Active Power Filter With a Low-Pass Filter as Input Stage   [View] 
 [Download] 
 Author(s)   O. Lopez Lapena; L. Garcia de Vicuña; J. Matas; M. López; M. Castilla 
 Abstract   Single-phase active filter and its sliding mode control design are presented. The proposed scheme consists of a conventional voltage-source inverter, in which a low-pass filter has been added as input stage. Consequently, the current ripple is reduced from the conventional structure, but an accurate controller design technique is needed to avoid the self-oscillation of the input filter. This paper demonstrates that a sliding mode control can be obtained, which permits the compensation of the harmonic distortion and phase displacement of the line current, by imposing a desired dynamic behavior on the system. 
 Download 
Filename:EPE1999 - PP00761 - Lopez Lapena.pdf
Filesize:192.3 KB
 Type   Members Only 
 Date   Last modified 2004-04-08 by System