Please enter the words you want to search for:

[Return to folder listing]

   Comparison of Practical Performance and Limits of Sensorless IM Drive Using a Closed Loop Flux Observer and a Full Order Flux Observer   [View] 
 [Download] 
 Author(s)   K. Ohyama; G. M. Asher; M. Sumner 
 Abstract   This paper compares the experimental performance of three flux and speed observers for speedsensorless induction motor drives. The three methods are generally accepted to be leading candidates for high sensorless performance: rotor-flux MRAS, torque-current MRAS and the adaptive non-linear flux observer. The paper discusses baseline conditions for the tests: these include matched load inertia, specified speed estimator dynamics and sensorless operation within a speed control loop. For the comparison tests in the paper, the speed estimation dynamics of the methods are approximately the same; this is important for parameter sensitivity. The paper concentrates on tests for zero and low speed performance and all results shown are under sensorless speed control. 
 Download 
Filename:EPE1999 - PP00741 - Ohyama.pdf
Filesize:173.5 KB
 Type   Members Only 
 Date   Last modified 2004-03-30 by System