Please enter the words you want to search for:

[Return to folder listing]

   Use of the Transformer Polygon Equivalent Circuit in Analysis of the Input Converter in AC Traction Drives   [View] 
 [Download] 
 Author(s)   G. Skarpetowski 
 Abstract   A closed analytical description of the AC supplied traction drive input circuit, including model of the single phase, multi-winding traction transformer and a model of the line side 4 quadrant converter is presented. The main attention is directed to the mathematical model of the multi-winding traction transformer. The polygon network model of the ā€œNā€ windings traction transformer is based on 0.5*(N-1)*N short circuit impedance measurements. The short circuit impedance is represented as a serial connection of frequency dependent resistors and frequency dependent inductors. The described transformer model is limited to the frequency range applied in short circuit measurements. The presented method, applied by the author, increases the accuracy of traction converter input circuit and harmonic filter dimensioning, allows for more exact calculation of current distortion and line converter components stresses. 
 Download 
Filename:EPE1999 - PP00231 - Skarpetowski.pdf
Filesize:90.94 KB
 Type   Members Only 
 Date   Last modified 2004-04-07 by System