Please enter the words you want to search for:

[Return to folder listing]

   Use of a normally-on GTO in a linear mode to commute lower than 1kW powers on 240 V/50Hz   [View] 
 [Download] 
 Author(s)   F. Guitton; D. Magnon 
 Abstract   STMicroelectronics has been developing ASD™ products that are well suited for mains network switching (50Hz). These direct commutations, achieved by a GTO structure, generate a lot of conducted electromagnetic perturbations, which are much higher than standard templates. Two solutions are proposed to reduce these perturbations. The first one consists in acting directly on the gate of the GTO. The second solution consists in controlling the turn off GTO current, by an external circuit. In this case, the GTO is used in a linear mode during the commutation. In spite of an increase of commutation losses, this system operates correctly, and offers interesting prospects for ASD™ applications, regarding the EMC aspect. 
 Download 
Filename:EPE1999 - PP00446 - Guitton.pdf
Filesize:137.7 KB
 Type   Members Only 
 Date   Last modified 2004-03-29 by System