Applying a Fast Analytic Calculation Method in CM Domain for Touch Currentsto a Two-Stage Charging Infrastructure
| [View]
[Download]
|
Author(s) |
Christian STUTZ, Sebastian NIELEBOCK, Martin MÄRZ |
Abstract |
Keeping touch & leakage currents within the tough regulation limits is a very ambitious goal for non-isolated EV-chargers, affecting the entire system setup (topology, PWM, filter). This paper improves the scope of a timesaving analytical touch current calculation method by expanding the modelling from a single-stage to a two-stage power electronic architecture. The analytic calculation workflow is validated with a laboratory setup including a 2-level 3-phase active front end converter and a H-bridge DC-DC-converter. Finally, the influence of different DC-DC-converter PWM schemes on the touch current behaviour of the charging system is analysed in detail. |
Download |
Filename: | 0279-epe2023-full-17172510.pdf |
Filesize: | 4.618 MB |
|
Type |
Members Only |
Date |
Last modified 2023-09-24 by System |
|
|