 Author(s)   Markus ZOCHER 
 Abstract   This paper demonstrates a method to reduce the voltage stress of the auxiliary transistors inside anARCP inverter. A saturable inductance softens the diode reverse recovery process. The proposedmethod has been successfully tested on a prototype converter over a wide range of currents, DC linkvoltages and switching frequencies. 