Please enter the words you want to search for:

[Return to folder listing]

   IPM synchronous machine drive response to short circuit faults   [View] 
 [Download] 
 Author(s)   B. A. Welchko; T. M. Jahns; W. L. Soong; J. M. Nagashima 
 Abstract   A closed-form solution is presented for the steady-state response of interior permanent magnet (IPM) synchronous machines to symmetrical short circuits including the effects of q-axis magnetic saturation. Machine response to single-phase asymmetrical short circuits is also investigated. Experimental data is presented to verify predicted behavior for both types of short circuits. It is shown that single-phase asymmetrical short circuit faults produce more severe fault responses with high pulsating torque and a significant threat of rotor demagnetization. A control strategy that purposely transitions such faults into symmetrical three-phase short circuits can minimize the fault severity and associated demagnetization risks. Implications for the design of IPM machines with improved fault tolerance are discussed. 
 Download 
Filename:EPE2001 - PP01216 - Welchko.pdf
Filesize:139 KB
 Type   Members Only 
 Date   Last modified 2004-03-09 by System