Abstract |
A closed-form solution is presented for the steady-state response of interior permanent magnet
(IPM) synchronous machines to symmetrical short circuits including the effects of q-axis magnetic
saturation. Machine response to single-phase asymmetrical short circuits is also investigated.
Experimental data is presented to verify predicted behavior for both types of short circuits. It is
shown that single-phase asymmetrical short circuit faults produce more severe fault responses with
high pulsating torque and a significant threat of rotor demagnetization. A control strategy that
purposely transitions such faults into symmetrical three-phase short circuits can minimize the fault
severity and associated demagnetization risks. Implications for the design of IPM machines with
improved fault tolerance are discussed. |