   Measurement of Parasitic High-Frequency Currents in Inverter-Fed Low-Speed Electrical Machines Using Rogowski Current Sensors   [View] 
 [Download] 
 Author(s)   Daniel HEIDE 
 Abstract   This paper presents the results of a high-frequency ground and bearing current measurement in an inverter-fed ac machine. The method is based on an assembly of Rogowski coils around the shaft and the main electrical cables and can be used in most electric drive systems without invasive system changes. 