   ADAPTIVE OPTIMAL PULSEWIDTH MODULATION FOR THE LINE-SIDE CONVERTER OF ELECTRIC LOCOMOTIVES   [View] 
 [Download] 
 Author(s)   Joachim Holtz; Jens Onno Krah 
 Abstract   Reflections of traveling waves in a distributed railway overhead supply system produce electrical oscillations at multiple resonant frequencies. These are likely to coincide with the characteristic harmonics of PWM converter-fed locomotives, which may produce electromagnetic interference with track-side communication lines. Resonant excitation of the line is avoided using an optimized PWM control of the line-side converter. The corresponding frequency bands are eliminated in the harmonic spectrum of the converter. An adaptive strategy takes care of the fact that the resonant frequencies are time-varying as the locomotives move along their tracks. The adaptive optimal control can be performed in real-time on a digital signal processor system. 