   MEASUREMENT OF THE REDISTRIBUTION OF CURRENT IN GTO THYRISTORS DURING TURN OFF   [View] 
 [Download] 
 Author(s)   P. R. Palmer; C. M. Johnson 
 Abstract   A method is described for measuring the redistribution of current that occurs between cathode islands in multi-cathode GTO Thyristors at turn-off. Current redistribution has implications for device reliability, since the maximum controllable current for a single island may be reached catastrophically. Results are presented for 400A GTO's showing that the extent of the current redistribution depends upon the storage time allowed, and the anode-cathode voltage reached during the current fall time. From this conclusions are made concerning GTO circuit design and rating of the devices. 
 Download 
Filename:Unnamed file
Filesize:421.5 KB
 Type   Members Only 
 Date   Last modified 2021-02-08 by System