A NEW MICROPROCESSOR-BASED CONTROL FOR HIGH POWER CYCLOCONVERTERS
| [View]
[Download]
|
Author(s) |
P. Bleus; J. Fafchamps; W. Legros; J. M. Bodson |
Abstract |
In cycloconverters, thyristor firing time is usually based upon an internal voltage control, which gives rise to some embarrassing penalties. Our paper will show how these disadvantages are strongly reduced with a direct command from a microprocessor-based current controller. A hierarchical microprocessor structure optimizes control functions, man/machine dialogue and diagnosis. Simulations and experiments on a 15 kVA prototype brought this development to a successful issue. A higher power equipment (3 MVA AC motor) is now being tested. |
Download |
Filename: | Unnamed file |
Filesize: | 1.793 MB |
|
Type |
Members Only |
Date |
Last modified 2021-02-03 by System |
|
|