NONLINEAR CONTROL CHARACTERISTICS OF PWM FOUR-QUADRANT CHOPPERS IN CURRENT CONTROL LOOPS
| [View]
[Download]
|
Author(s) |
Rolf-Dieter Klug |
Abstract |
This paper describes the effects of the switching dead times - protecting the power switches by avoiding a bridge leg short circuit in PWM amplifiers - on the control characteristic first generally for one bridge leg (2-quadrant d.c. chopper), then for circuits with two (4-quadrant d.c. chopper) and three (3-phase inverter) bridge legs at resistive-inductive-active load operation. The effect of the resulting ambiguous and non-linear control characteristic on the current control loop is shown exemplary for the 4-quadrant d.c. chopper. A signal processing correction circuit for the PWM control signal is presented to get a definite and linear behaviour of the mentioned bridge amplifiers. The results are shown at a 4-quadrant d.c. chopper. |
Download |
Filename: | Unnamed file |
Filesize: | 3.767 MB |
|
Type |
Members Only |
Date |
Last modified 2021-02-01 by System |
|
|