Saliency Selection for Search-based AC Machine Low and Zero Speed Estimation Methods
| [View]
[Download]
|
Author(s) |
Kris SCICLUNA |
Abstract |
This paper presents the analysis and selection of a suitable injection angle to be used with continuous pulsating injection and search-based sensorless control. Pulsating injection offers the possibility of different injection orientations in the stationary reference frame. The injection results in High-Frequency current signatures, which vary in shape and magnitude due to the multiple saliency harmonics on the experimental Permanent Magnet Synchronous Machine. The analysis and selection process presented in this paper aims to reduce the implementation time for robust sensorless control. Experimental results are presented for different injection angles and iq-current operating points. |
Download |
Filename: | 0279-epe2020-full-11013359.pdf |
Filesize: | 1.19 MB |
|
Type |
Members Only |
Date |
Last modified 2021-01-18 by System |
|
|