Abstract |
In contrast to common 3-phase topologies, DC-link capacitance can be reduced by combining inputpower after the DC-link using a multi-port transformer and suitable control. Initial results of this approach demonstrate stable 12 kW output power using only 5 µF DC-link capacitance per phase, promising higher power density and reliability. Furthermore, a novel control scheme is proposed that allows high frequency reactive power flow through the multi-port transformer to be manipulated via gate-signal phase angles, in order to achieve maximum efficiency and minimum DC-link voltage ripple for any load condition. |