Influence of winding position on the inductance of hf-transformers
| [View]
[Download]
|
Author(s) |
S. Voss; H. Roßmanith; M. Albach |
Abstract |
The number of turns needed for the realisation of a given inductance on a given core is normally
calculated by means of the AL-value specified in data books. Unfortunately this AL-value is not a
constant value, a variation of the inductance L of 70% has been measured only by changing the
position of the turns inside the winding area. In this paper the influence of the gap position and
especially of the position of the turns on the AL-value is demonstrated and the necessary equations for calculating this influence are presented. |