Please enter the words you want to search for:

[Return to folder listing]

   DC Voltage and Torque Ripple Mitigation in Modular PMSG Drives for Off-Shore Multi-MW WECSs with Linear SPWM modulation   [View] 
 [Download] 
 Author(s)   Khaled ELSHAWARBY 
 Abstract   A multi-modular axial flux machine is used for wind energy conversion systems (WECSs) where eachmodule is connected to its own two-level converter. All converters are connected in series at the DCside to allow HVDC transmission. In the paper, an in-depth reasoning for the control of each individualvoltage. A phase shift between PWM carrier signals of the neighbouring converters is implemented. Amathematical analysis is carried out. A criterion for the best choice of the phase shift to minimize dcvoltage and torque harmonics is proposed. 
 Download 
Filename:0220-epe2019-full-17050127.pdf
Filesize:1.781 MB
 Type   Members Only 
 Date   Last modified 2020-08-14 by System