   LOW LOSSES NEW SNUBBER CIRCUIT FOR HIGH POWER GTO INVERTER APPLICATION. TESTS AND RESULTS   [View] 
 [Download] 
 Author(s)   V. Gilblas; F. Favo 
 Abstract   Voltage source GTO lnverters need protection circuits to limit di/dt and dv/dt. These circuits, in the case of high power converters as in traction applications, have the disavantage of requiring a large room and of reducing the inverter's efficiency. This paper describes the application of a new low losses circuit in a 1.5 MW inverter used in high power locomotlve. Design criteria, tests and results are shown and dlscussed. 
 Download 
Filename:Unnamed file
Filesize:2.669 MB
 Type   Members Only 
 Date   Last modified 2019-08-15 by System