   Side effects of LISN on EMI measurements in power converters   [View] 
 [Download] 
 Author(s)   J. Balcells; D. González; J. Gago; M. Lamich 
 Abstract   Several measurements were performed on a power converter to obtain a model which allowed the prediction of conducted EMI . The goal was to identify the relevant components and lay-out parameters influencing the EMI generation and transmission. Some of the measured disturbances could not be attributed to any real or parasitic component in the converter and finally, it was found that they came from the measuring set-up (namely from the standard LISN and the measuring through the high pass surge suppression filter, HPF). The introduction of real models for the measuring equipment in the simulation, allowed a precise coincidence between simulated and measured EMI and showed that the standard measuring equipment introduce some extra disturbances which are no present in the normal working conditions. 