 Author(s)   S. lto; K. Imaie; K. Nakata; S. Ueda; K. Nakamura 
 Abstract   PWM methods of a multiple inverter for adjustable frequency drive have been investigated. In a multiple inverter, of which configuration inevitably includes transformers connecting output terminals of unit inverters, voltage-time product should be reduced especially in lower frequency region, otherwise magnetic saturation of the transformer cores can occur. Suppression of harmonic components is another important consideration to prevent torque ripple and electromagnetic interference. It is, however, very difficult for a single PWM method to cover the whole operational frequency region, keeping both the voltage-time product and the harmonics reduced. Here, a series of PWM methods are proposed; low, medium and high speed region PWMs. They are changed depending on the output frequency of the inverter, and reduces voltage-time product and harmonics in each operational frequency region. Simulations and experimental results using small capacity test circuit show the effectiveness of the methods. 