   REMEDIAL STRATEGY FOR INVERTER-INDUCTION MACHINE SYSTEM FAULTS USING TWO-PHASE OPERATION   [View] 
 [Download] 
 Author(s)   T. Elch-Heb; J. P. Hautier 
 Abstract   In this paper the authors present an optimal remedial strategy for Inverter - Three phase induction machine system drive faults. Remedial strategy can be a single-phase operation when neutral point of star coupled induction machine is not connected, and is a two-phase operation when neutral point is connected to dc Source Voltage of a Current Controlled lnverter. In this case ripple component, which is unavoidable in single-phase operation, can be supressed when current references are pi/3 shifted. This optimal two-phase operation mode can be used to perform field-oriented control as in three-phase operation. Obtained performances with two-phase operation are then similar to those of three-phase mode but with currents magnitude V3 more important. 