   Online Impedance Spectroscopy Estimation of a dc-dc converter connected Battery using an Earth Leakage Monitoring Circuit   [View] 
 [Download] 
 Author(s)   Mina ABEDI VARNOSFADERANI 
 Abstract   Electrochemical Impedance Spectroscopy (EIS) techniques are useful tools for being able to look atthe characterisation of batteries under different conditions and/or with different material components.However, EIS analysis is mostly undertaken offline with bespoke equipment. This paper describes amethod of undertaking EIS measurement on-line without the use of additional equipment bymanipulating the earth leakage monitoring circuit to generate low frequency excitation signals to analysea battery system connected to a dc/dc converter. This paper describes the methodology and presentssome experimental results compared with off line EIS results generated with more traditional EISequipment under the same conditions to illustrate the concept. 
 Download 
Filename:0068-epe2017-full-11373904.pdf
Filesize:457 KB
 Type   Members Only 
 Date   Last modified 2018-04-17 by System