Abstract |
The paper will give a detailed presentation of an active power cycling test bench in high
temperature conditions developed to ageing the solder between the Direct Copper Bonding (DCB) and
the base of IGBT devices. The average junction temperature measurement protocol, the temperature
regulation of the base plate, the acquisition of all the electrical signals, and the performance of the test
circuit will be presented and discussed. Moreover, a thermal modelling presentation has been used to
define the power cycling test parameters. The paper will present results of long time power cycling
tests in server working conditions in the case of a base plate temperature equal to 90 °C, for a power