Please enter the words you want to search for:

[Return to folder listing]

   RECOVERY OF AN INVERTING MODE COMMUTATION FAILURE IN THE CASE OF A THREE PHASE D.C. THYRISTOR BRIDGE CONTROLLED BY A DIGITAL DEVICE   [View] 
 [Download] 
 Author(s)   J-P. Sawicki; J-F. Aubry; C. Zanne 
 Abstract   In this paper, we present a strategy to recover commutation failures in nonautonomous inverting mode. We intend to improve the performances of any electromechanical process working in this mode while warranting its dependability. Steady states like transient events, normal or faulty, are described accurately with the help of state graph. A firing sequence reconfiguration is deduced from all the possibilities to switch on thyristors in the static converter. The recovery strategy is tested on a bench composed of two D.C machines : the side effects of the procedure are minimized in delaying the recovery pair and in resetting properly the armature current controller. 
 Download 
Filename:Unnamed file
Filesize:499.6 KB
 Type   Members Only 
 Date   Last modified 2018-04-12 by System