Elimination of vector changes due to sector changes with DTC
| [View]
[Download]
|
Author(s) |
Georg Tolstoy; Oskar Wallmark; Staffan Norrga; Hans-Peter Nee; Björn Larsson |
Abstract |
In this paper it has been investigated if there is a possibility to reduce the switching frequency for a two-level inverter by improving the direct torque control (DTC) algorithm by adding a non-switching condition when a new sector is entered. It is believed that the DTC switching table can be improved by adding a non-switching condition when sector change occurs. This will reduce the number of switching actions by up to 12 per electrical rotation without interfering with the electrical machine performance. |
Download |
Filename: | Unnamed file |
Filesize: | 334.4 KB |
|
Type |
Members Only |
Date |
Last modified 2017-06-30 by System |
|
|