Please enter the words you want to search for:

[Return to folder listing]

   Loss analysis of Z-source Inverter Using SiC-MOSFET from the Perspective of Current Path in the Short-through Mode   [View] 
 [Download] 
 Author(s)   Ryuji IIJIMA 
 Abstract   This paper discusses suitable short-through mode for a Z-source inverter using SiC-MOSFET to achieve high switching frequency operation. The Z-source inverter has short-through mode for boost operation and several control techniques about short-through mode have been discussed from points of device stress and boost ratio; however, loss analysis from perspective of short-through mode implementation has not been studied well, especially in the case of using SiC-MOSFET. Losses with two types of short-through mode and three switching frequencies are investigated experimentally. As a result, it was confirmed that the conduction loss and switching loss of the Z-source inverter can be reduce by employing a 3-leg short through mode. 
 Download 
Filename:0631-epe2016-full-19553060.pdf
Filesize:1.127 MB
 Type   Members Only 
 Date   Last modified 2017-04-13 by System